from 27 February 2017 to 3 March 2017
Budker Institute of Nuclear Physics
Asia/Novosibirsk timezone
Home > Timetable > Session details > Contribution details

Contribution Contributed Oral

Electronics, Trigger and Data Acquisition

Front-End Electronics development status for TPC detector of MPD/NICA project

Speakers

  • Mr. Stepan VERESCHAGIN

Primary authors

Content

The TPC is placed in the center of a Multi Purpose Detector comprising the interaction point of colliding beams together with other central detectors that provides the recovery and identification of charged particle tracks in the pseudorapidity’s range |η|≤ 1.2 in future NICA collider experiments. The readout system is one of the most complex parts of the TPC. The electronics of each readout chambers is an independent system. The whole system contains 95232 channels, 1488 64-ch. front-end cards (FEC), 24 readout control units (RCU). The front-end electronics (FEE) based on modern ASICs, FPGA and high-speed serial links. Development status, measurement results and possible design improvements of the TPC front-end electronics presented.