BEGIN:VCALENDAR
VERSION:2.0
PRODID:-//CERN//INDICO//EN
BEGIN:VEVENT
SUMMARY:Pulsed wire field measurements of 38-period superconducting undula
 tor prototype
DTSTART;VALUE=DATE-TIME:20200713T131800Z
DTEND;VALUE=DATE-TIME:20200713T131900Z
DTSTAMP;VALUE=DATE-TIME:20260419T045857Z
UID:indico-contribution-1820@indico.inp.nsk.su
DESCRIPTION:Speakers: Fedor Kazantsev (Novosibirsk State University)\nIn t
 his paper\, a pulsed wire method (PWM) for magnetic measurements was descr
 ibed. Experimental setup was developed and assembled. The results of measu
 rements on superconductive 38-pole 0.75 T undulator are given. Two differe
 nt wires were used – 200µm and 140 µm diameter. For 140µm the calibra
 tion curve was obtained\, wire position sensor has high sensitivity – 0.
 28 V/µm. A dispersion correction algorithm was applied to the raw data fr
 om sensor and corrected signals were given. The results and further works 
 are being discussed.\n\nhttps://indico.inp.nsk.su/event/24/contributions/1
 820/
LOCATION:
URL:https://indico.inp.nsk.su/event/24/contributions/1820/
END:VEVENT