BEGIN:VCALENDAR
VERSION:2.0
PRODID:-//CERN//INDICO//EN
BEGIN:VEVENT
SUMMARY:Power supply system for corrector magnets of the European X-Ray Fr
 ee-Electron Laser
DTSTART;VALUE=DATE-TIME:20160705T090000Z
DTEND;VALUE=DATE-TIME:20160705T100000Z
DTSTAMP;VALUE=DATE-TIME:20260417T100313Z
UID:indico-contribution-1295@indico.inp.nsk.su
DESCRIPTION:Speakers: Oleg Belikov (Budker INP SB RAS)\nTotal length of th
 e European X-Ray Free-Electron Laser (European XFEL) tunnel is 3\,4 km. Th
 ere are used about 300 magnet correctors to justify position of electron b
 eam. Each magnet is feed by separate power supply with high parameters. To
  have a stable beam the short time (up to 1 sec) deviation of output curre
 nt should be less than 10^-5\, long term stability should be better than10
 ^-4. For this application the BINP SB RAS developed 7 types of power suppl
 ies with output current up to 10 A and output voltage up to 70 V. To provi
 de high reliability of power supply system there was developed “hot repl
 ace” system allowing remote replacement failed power supply by reserved 
 one. Now the power supply system is introducing in operation. The paper is
  reviewing details of power supply system for European XFEL.\n\nhttps://in
 dico.inp.nsk.su/event/3/contributions/1295/
LOCATION:Budker INP 2nd and 3rd floors
URL:https://indico.inp.nsk.su/event/3/contributions/1295/
END:VEVENT
END:VCALENDAR