Vertical Test Stand (VTS) and Horizontal Test Stand (HTS) Facilities are set-up at RRCAT for testing and qualification of Superconducting Radio Frequency (SCRF) Cavities. VTS facility is operational since 2013 and tested many single cell and multi-cell 1.3 GHz and 650 MHz cavities at 2 Kelvin. HTS is in its commissioning trials. HTS cryostat designed for cooling down two 650 MHz dressed SCRF cavities with RF powering of one cavity at a time. Operation of VTS needs to handle around 5000 liters of liquid helium and HTS operation requires to produce 4.5 K helium in super-critical state in order to achieve 2 K in these facilities. Large scale cryogenic facilities are set-up and being upgraded to operate these facilities successfully. Present talk summarizes the cryogenic requirement and facilities created for successful operation of SCRF cavity test stands.

Primary author

Prabhat Gupta (RRCAT Indore)

Co-authors

Manoj Kumar (RRCAT) R.K. Sharma (RRCAT Indore) Vivek Nema (RRCAT,Indore) RS Doohan (RRCAT, Indore) S Raghavendra (RRCAT,Indore) P Shrivastava (RRCAT, Indore)