SUMMARY:Novel Fast Response and Radiation-resistant Scintillator Detector 
 for Beam Loss Monitor
DTSTART;VALUE=DATE-TIME:20170228T100000Z
DTEND;VALUE=DATE-TIME:20170228T110000Z
DTSTAMP;VALUE=DATE-TIME:20261118T173055Z
UID:indico-contribution-1634@indico.inp.nsk.su
DESCRIPTION:Speakers: Yuanjing Ji (University of Science and Technology of
  China)\nAt high luminosity era\, beam loss monitor with fast response and
  good radiation resistance is crucial for smooth and safe operation of col
 lider. Due to high intensity of the beam\, even a small amount of beam los
 s may cause cooling issue and serious damage to accelerator components and
  radiation sensitive equipment. The ultimate goal of a beam loss monitor s
 ystem at a high intensity beam is to identify the loss level and\, if poss
 ible\, the loss location and time structure and to be able to protect the 
 machine at uncontrolled loss (detect the uncontrolled loss as soon as poss
 ible and shut down the accelerator in microsecond level). This requires th
 e beam loss monitor has fast response and excellent radiation resistance. 
 The traditional ionization chamber\, plastic (liquid) scintillator+PMT\, P
 IN diodes etc has difficulties to satisfy all of the requirements.\n\nIn t
 his talk\, we will report the design and test results of a fast response a
 nd radiation-resistant scintillator detector as the beam loss monitor of h
 igh intensity beam at low energy part such as RFQ. The detector is consist
 ent of a 2cm x 2cm x 0.5 cm LYSO crystal readout by a 0.6 cm x 0.6 cm Sili
 con photomultiplier (SiPM). LYSO features high light yield\, short decay t
 ime\, relative dense and very good radiation resistance (2 orders of magna
 te higher than plastic scintillator). And SiPM has many advantages compare
 d to PMT. It is compact\, economy\, insensitive to magnetic field and has 
 low working voltage\, good charge resolution and broad spectra response. T
 he detectors we constructed have been tested with various radioactive sour
 ces. The test results show that the detector has good sensitivity to photo
 n at energy range of a few keV to tens of MeV and charged particles with g
 ood linearity and energy resolution (23% for 60 keV X-ray). Two detectors 
 (one parallel to and the other perpendicular to the beam) are installed ou
 tside of the vacuum chamber shell of a 800 MeV electron storage ring and t
 ested. The detail of the test and results will also be reported. Furthermo
 re\, the implication in the electromagnetic calorimeter based on fast resp
 onse crystal and SiPM readout for the high intensity electron positron acc
 elerator facility in China will be discussed.\n\nhttps://indico.inp.nsk.su