Test results of the aerogel Cherenkov counters with n=1.05 using electrons and muons at p<500 MeV/c

Speakers

  • Karina MARTIN

Primary authors

Abstract content

Test results of the threshold aerogel Cherenkov counters system with n=1.05 intended for particle separation are presented. The system is constructed for SND detector which is taking data at VEPP-2000 e⁺e⁻ collider. The measurements have been done using particles from e⁺e⁻ → e⁺e⁻ and e⁺e⁻ → μ⁺μ⁻ reactions. The average signal from electrons is 3.5 photoelectrons.