Recent Achievements in Studies of Negative Beam Formation and Acceleration in the Tandem Accelerator at Budker Institute

9 Sep 2020, 03:00
20m
Oral Beam lines and facilities O4

Speaker

Andrey Sanin (Budker Institute of Nuclear Physics)

Description

A continuous-wave surface-plasma negative hydrogen ion source is used to inject a negative ion beam into tandem accelerator with vacuum insulation at Budker Institute of Nuclear Physics since 2006. In the ion source, Penning discharge with plasma injection from hollow cathodes and cesium seeding is applied to generate a negative ion beam with a current up to 10 mA at 25 KV acceleration voltage. Due to several updates to the ion source and the tandem, maximum output proton beam current of up to 8 mA at 2 MeV is obtained. The results obtained recently in studies of ion beam formation and acceleration in the tandem accelerator are discussed

Primary authors

Andrey Sanin (Budker Institute of Nuclear Physics) Prof. Yuri Belchenko (Budker Institute of Nuclear Physics) Igor Gusev (Budker Institute of Nuclear Physics) Ivan Emelev (Budker Institute of Nuclear Physics) Alexander Ivanov (Budker Institute of Nuclear Physics) Anatoliy Gmyrya (Budker Institute of Nuclear Physics) Vladimir Rashchenko (Budker Institute of Nuclear Physics) Dr Valery Savkin (Budker Institute of Nuclear Physics) Ivan Shchudlo (Budker Institute of Nuclear Physics) Dr Igor Sorokin (Budker Institute of Nuclear Physics) Dr Sergey Taskaev (Budker Institute of Nuclear Physics) Dr Peter Zubarev (Budker Institute of Nuclear Physics)

Presentation Materials

Peer reviewing

Paper